quietcool trident pro x mounted in attic

QuietCool Trident Pro X Series

The Trident Pro line, compared to the QuietCool Stealth Pro X,  consists of several models ranging from the 1,500 CFM all the way up to 7,000 CFM! There are also different speed options depending on the unit. These options allow homeowners to control how much airflow they want to move through their home. The Trident Pro series has a permanent split capacitor (PSC) motor which is extremely dependable and very common in many electronic products. Also included with the unit; a switch and timer.

quietcool trident pro 1.5x

Product Specifications

– Motor Voltage: 120 VAC, 60 Hz

– Energy Use: 115 Watts

– Air Flow: 1498 CFM

– Recommended SQFT Coverage @2CFM per SQFT: Covers up to 750 SQFT

– Number of Speeds: 1

– Duct Diameter: 14″

– Duct Length: 6ft.

– Motor Head Diameter: 14 1/2″

– Motor Head Length: 13 1/2″

– Dampers: Barometric Pressurized R5 Dampers

– Controls: included 8 Hour Electronic Timer

– Warranty: 15 years

– Framing: None Required

– Joist Cutting: None Required; fits 16″ or 24″ on center

– Minimum Suggested Attic Venting: 2 SQFT net free area

– Ceiling Rough Opening: 14 1/4″ x 14 1/4″

– Removable Grille Outside Dimension: 16″ x 16″

quietcool trident pro 2.5x

Product Specifications

– Motor Voltage: 120 VAC, 60 Hz

– Energy Use: Hi: 244 Watts / Low: 198 Watts

– Air Flow: Hi: 2490 CFM / Low: 1934 CFM

– Recommended SQFT Coverage @2CFM per SQFT: Covers up to 1250 SQFT

– Number of Speeds: 2

– Duct Diameter: 16″

– Duct Length: 6ft.

– Motor Head Diameter: 16 1/2″

– Motor Head Length: 13 1/2″

– Dampers: Barometric Pressurized R5 Dampers

– Controls: included 8 Hour Electronic Timer and HI-LOW-OFF Switch

– Warranty: 15 years

– Framing: None Required

– Joist Cutting: None Required; fits 16″ or 24″ on center

– Minimum Suggested Attic Venting: 3.32 SQFT net free area

– Ceiling Rough Opening: 14 1/4″ x 18 1/4″

– Removable Grille Outside Dimension: 16″ x 20″

quietcool trident pro 3.3x

Product Specifications

– Motor Voltage: 120 VAC, 60 Hz

– Energy Use: Hi: 323 Watts / Low: 274 Watts

– Air Flow: Hi: 3216 CFM / Low: 2890 CFM

– Recommended SQFT Coverage @2CFM per SQFT: Covers up to 1610 SQFT

– Number of Speeds: 2

– Duct Diameter: 16″

– Duct Length: 6ft.

– Motor Head Diameter: 16 1/2″

– Motor Head Length: 13 1/2″

– Dampers: Barometric Pressurized R5 Dampers

– Controls: included 8 Hour Electronic Timer and HI-LOW-OFF Switch

– Warranty: 15 years

– Framing: None Required

– Joist Cutting: None Required; fits 16″ or 24″ on center

– Minimum Suggested Attic Venting: 4.29 SQFT net free area

– Ceiling Rough Opening: 14 1/4″ x 22 1/4″

– Removable Grille Outside Dimension: 16″ x 24″

quietcool trident pro 4.8x

Product Specifications

– Motor Voltage: 120 VAC, 60 Hz

– Energy Use: Hi: 555 Watts / Low: 417 Watts

– Air Flow: Hi: 4428 CFM / Low: 3436 CFM

– Recommended SQFT Coverage @2CFM per SQFT: Covers up to 2220 SQFT

– Number of Speeds: 2

– Duct Diameter: 16″

– Duct Length: 9ft.

– Motor Head Diameter: 18 1/2″

– Motor Head Length: 13 1/2″

– Dampers: Barometric Pressurized R5 Dampers

– Controls: included 8 Hour Electronic Timer and HI-LOW-OFF Switch

– Warranty: 15 years

– Framing: None Required

– Joist Cutting: None Required; fits 16″ or 24″ on center

– Minimum Suggested Attic Venting: 5.91 SQFT net free area

– Ceiling Rough Opening: 14 1/4″ x 30 1/4″

– Removable Grille Outside Dimension: 16″ x 32″

quietcool trident pro 5.5x

Product Specifications

– Motor Voltage: 120 VAC, 60 Hz

– Energy Use: Hi: 632 Watts / Low: 522 Watts

– Air Flow: Hi: 5068 CFM / Low: 4438 CFM

– Recommended SQFT Coverage @2CFM per SQFT: Covers up to 2540 SQFT

– Number of Speeds: 2

– Duct Diameter: 20″

– Duct Length: 9ft.

– Motor Head Diameter: 20 1/2″

– Motor Head Length: 13 1/2″

– Dampers: Barometric Pressurized R5 Dampers

– Controls: included 8 Hour Electronic Timer and HI-LOW-OFF Switch

– Warranty: 15 years

– Framing: None Required

– Joist Cutting: None Required; fits 16″ or 24″ on center

– Minimum Suggested Attic Venting: 6.76 SQFT net free area

– Ceiling Rough Opening: 14 1/4″ x 30 1/4″

– Removable Grille Outside Dimension: 16″ x 32″

quietcool trident pro 6.0x

Product Specifications

– Motor Voltage: 120 VAC, 60 Hz

– Energy Use: Hi: 777 Watts / Low: 560 Watts

– Air Flow: Hi: 5708 CFM / Low: 4319 CFM

– Recommended SQFT Coverage @2CFM per SQFT: Covers up to 2860 SQFT

– Number of Speeds: 2

– Duct Diameter: 22″

– Duct Length: 9ft.

– Motor Head Diameter: 22 1/2″

– Motor Head Length: 13 1/2″

– Dampers: Barometric Pressurized R5 Dampers

– Controls: included 8 Hour Electronic Timer and HI-LOW-OFF Switch

– Warranty: 15 years

– Framing: None Required

– Joist Cutting: None Required; fits 16″ or 24″ on center

– Minimum Suggested Attic Venting: 7.62 SQFT net free area

– Ceiling Rough Opening: 14 1/4″ x 36 1/4″

– Removable Grille Outside Dimension: 16″ x 38″

quietcool trident pro 7.0x

Product Specifications

– Motor Voltage: 120 VAC, 60 Hz

– Energy Use: Hi: 1147 Watts / Low: 797 Watts

– Air Flow: Hi: 7015 CFM / Low: 5548 CFM

– Recommended SQFT Coverage @2CFM per SQFT: Covers up to 3510 SQFT

– Number of Speeds: 2

– Duct Diameter: 24″

– Duct Length: 9ft.

– Motor Head Diameter: 24 1/2″

– Motor Head Length: 13 1/2″

– Dampers: Barometric Pressurized R5 Dampers

– Controls: included 8 Hour Electronic Timer and HI-LOW-OFF Switch

– Warranty: 15 years

– Framing: None Required

– Joist Cutting: None Required; fits 16″ or 24″ on center

– Minimum Suggested Attic Venting: 9.36 SQFT net free area

– Ceiling Rough Opening: 14 1/4″ x 36 1/4″

– Removable Grille Outside Dimension: 16″ x 38″